Energy Monitoring Solutions Measure, compare and reduce electricity, natural gas, heat and compressed air use, machine by machine

Knowing which department, line or machine uses how much energy is the first step towards accurate production costing and better efficiency. The utility bill only tells you the total; an energy monitoring system shows you where that total comes from.

Data from the meters and analysers in your plant is collected in a single software and recorded hourly, daily, per shift, weekly, monthly and yearly. When periods, departments and machines are compared side by side, hidden losses come to light and you get a measurable starting point for improvement.

What is energy monitoring?

Energy monitoring is the continuous, automatic measurement and recording of every type of energy used in a facility, turned into information people can act on. Instead of reading meters by hand and typing them into a spreadsheet, data flows into a central system in real time and everyone looks at the same up-to-date figures.

The measured consumption guides both the cost analysis of production processes and efficiency calculations. It shows what a product really costs and which investment should come first.

Systems that can be installed

SystemWhat is measured?
Electricity monitoringActive and reactive energy, power, current, voltage, power factor and power quality
Natural gas monitoringInstant flow (m³/h), total consumption; use per boiler, oven and burner
Hot water heat monitoringFlow, supply and return temperature and heat energy (kWh) via heat meters
Compressed air monitoringFlow, line pressure, compressor run times and consumption caused by leaks

Other utilities such as water, steam and nitrogen can be added to the same system when needed.

Fast installation with wireless solutions

Energy monitoring is usually done by fitting an energy analyser to each machine or panel. In the classic approach each analyser is wired to a collection point; in a large factory this means long cable routes, trunking work and a lengthy installation.

With our wireless solutions we can roll out energy monitoring in your factory much faster. Data from analysers and meters is collected over a wireless network, and adding a new machine becomes as simple as fitting and configuring a device.

  • Cabling and trunking costs are kept to a minimum
  • Installation time is significantly shorter
  • Commissioning can often be done without stopping production
  • Meters and analysers already in the plant can be included

Wired and wireless structures can be combined in the same project. The best mix is chosen together based on the plant layout and existing infrastructure.

How does an energy monitoring system work?

The system is built in layers, from the measuring device in the field to the user's screen. Each layer processes the data it receives and passes it on to the next.

Field Data collection Central Users Energy analyserelectricity Natural gas meterm³/h Heat meterhot water, heat Flow metercompressed air PLC / RTUwired line Gatewaywireless: LoRa, Wi-Fi SCADAlive view, alarms Databasehistory Web and mobileaccess anywhere Alarmse-mail, SMS ReportsExcel, PDF AI analysisanomaly, forecast Wired connection Wireless connection
  • Field: Energy analysers, gas meters, heat meters and flow meters measure consumption.
  • Data collection: PLCs, RTUs or wireless gateways poll the devices at set intervals and send the data to the centre.
  • Central: The SCADA software shows data live, checks limits and stores every value in the database.
  • Users: Reports, alarms and analyses reach the right people through a web browser or mobile device.

Real-time energy tracking

Measured values reach the screen within seconds. The energy manager and operators see the current state of the plant without walking the floor, and a boiler or line drawing more than expected is noticed straight away.

  • Instant power (kW)
  • Current (A)
  • Voltage (V)
  • Active energy (kWh)
  • Reactive energy (kVArh)
  • Cos φ
  • Frequency (Hz)
  • Flow (m³/h)
  • Instant and total consumption
Measuring pointInstantToday's total
Boiler 142.6 m³/h4,820 kWh
Paint shop oven128.4 kW2,315 kWh
Compressor line7.8 m³/min1,140 kWh
Heat meterSupply 82 °C, return 64 °C3,260 kWh

The values in the table are examples; screens are designed around the measuring points in your plant.

Energy analysis

Recorded data shows its real value over time. When the same day, shift or month is placed next to other periods, changes in consumption and their causes become visible.

  • Hourly, daily, per-shift, weekly, monthly and yearly consumption
  • Consumption trends and period comparisons
  • Peak moments and the equipment running at those times
  • Base load analysis: energy drawn even when nothing is produced
  • Consumption broken down by department, line and machine
Off hoursOff hoursProduction shift 0 100 200 00:00 03:00 06:00 09:00 12:00 15:00 18:00 21:00 Base load Peak kW Hour
  • Production hours
  • Off hours
  • Base load

A high base load at night or at weekends usually points to equipment left running, leaks or auxiliary systems working without need.

Power quality monitoring

The quality of energy matters as much as the quantity. Poor power quality causes overheating in motors and drives, failures in sensitive devices, problems in compensation systems and unexpected stoppages. Continuous monitoring finds the source before the fault grows.

ParameterWhy monitor it?
Voltage and currentDetecting overloads and unbalanced loads
FrequencyStability of grid or generator supply
Harmonics (THD)Effect of drives and rectifiers on the network, extra heating and losses
Power factorSeeing reactive energy penalty risk in advance
Phase imbalanceEfficiency loss in motors and shorter equipment life
Voltage sags and swellsFinding the cause of sudden stoppages and device failures

Machine and line level monitoring

The most valuable question energy monitoring answers is: how much energy does each machine use? The total bill cannot answer it; machine-level measurement links consumption to its real owner.

  • Consumption per machine
  • Consumption per production line
  • Consumption per department and building
  • Energy use per product

Combined with production data, the energy performance of two lines making the same product can be compared. Equipment that does the same job with more energy is easy to spot, and maintenance or replacement decisions are based on measurement.

Energy performance indicators (KPIs)

Raw consumption figures alone can be misleading; consumption naturally rises when output rises. That is why energy is tracked in relation to the amount produced.

IndicatorWhat does it show?
kWh / unitElectrical energy used to produce one part
kWh / tonneEnergy intensity in weight-based production
m³ natural gas / tonneThermal efficiency of ovens and boilers
Energy cost / productThe real energy share of product cost
Peak power (kW)The most critical moment for contracted power and tariffs
Base load ratio (%)Share of energy used while nothing is produced
Total energy consumptionOverall performance against period targets

Meter reading, bill checking and cost analysis

The system reads all meters automatically and calculates consumption for the time periods you define. The sum of department meters is compared with the bill from the electricity distributor or gas supplier and tracked weekly and monthly.

This comparison shows each department's consumption clearly and allocates costs to the right cost centres. Differences between the main meter and sub-meters point to losses or unmetered consumption, while differences between the bill and the measurements make it possible to spot incorrectly calculated energy bills.

Cost and tariff analysis

  • Unit cost per kWh and consumption cost
  • Calculation by single-rate and multi-rate tariffs
  • Separation of daytime, peak and night consumption
  • Energy cost per department and per product
  • Estimated bill for the end of the period

Alarms and notifications

The system checks the defined limits continuously and warns you when something goes wrong, without waiting for the bill at the end of the month.

  • Consumption above the planned value
  • Power demand limit exceeded
  • Low power factor and reactive penalty risk
  • Power quality problems
  • Meter and communication failures
  • Consumption continuing outside working hours

In critical situations the responsible person is reached by e-mail, SMS or mobile notification in addition to the on-screen alarm.

Reporting

Reports are where data reaches decision makers. Ready templates can be used, and custom reports are prepared around the indicators your business follows.

  • Hourly, daily and shift reports
  • Weekly, monthly and yearly reports
  • Energy cost reports
  • Department and machine comparisons
  • Excel and PDF output
  • Reports created automatically at set times and sent by e-mail

Measurement and record data needed for ISO 50001 energy management work can also be taken from these reports.

AI-assisted energy analysis

Artificial intelligence learns the plant's normal consumption behaviour from historical data. By detecting deviations from that behaviour it identifies likely losses and saving opportunities before problems grow.

  • Automatic detection of abnormal consumption
  • Consumption and bill forecasting
  • Linking consumption to output, shifts and weather
  • Uncovering unnecessary consumption
  • Ranking saving opportunities by impact

Energy saving and optimisation

The goal is not only to answer "how much do we use?". The real questions are: where do we use it, why do we use it and how can we reduce it?

Losses commonly found on site

  • Equipment still running outside working hours
  • Compressed air leaks
  • Pumps and fans running without need
  • Inefficient ovens and heating systems
  • Lines using high energy per product

Optimisation steps

  • Stopping equipment that runs without need
  • Spreading peak load over time
  • Tracking reactive energy and compensation
  • Prioritising replacement of inefficient equipment
  • Calculating saving potential from measurement

Integration with SCADA

The energy monitoring system works together with your existing automation infrastructure. PLCs, industrial meters and analysers in the field connect over common industrial protocols.

  • Modbus RTU
  • Modbus TCP
  • OPC UA
  • MQTT
  • Profinet
  • DNP3
  • IEC 60870-5-104
  • IEC 61850
  • PLC
  • Industrial meters

Energy data can be added to your existing SCADA system or set up as a stand-alone energy monitoring application with ATLAS SCADA. The collected data can also be passed to MES, ERP and reporting systems.

Substation monitoring

Energy monitoring does not stop at the factory wall. At high-voltage-fed plants, industrial-zone distribution centres, the grid connection points of wind and solar farms, and TEİAŞ (Turkish transmission system operator) substations, the status and measurements of every feeder in the switchyard are followed live through SCADA.

Here, measurements come not from utility meters but directly from protection relays and feeder control units. These devices are gathered at the station gateway, translated into standard protocols and passed to the SCADA screen in the control room and, where required, to the upstream dispatch centre.

Substation monitoring structure: SCADA workstation, redundant gateways, station network, protection relays and meters
The communication chain from the SCADA workstation in the control room down to the relays and meters in the switchyard
  • IEC 60870-5-104 (TCP/IP)
  • IEC 61850 MMS
  • IEC 60870-5-103 (Serial)
  • Modbus RTU / TCP
  • GPS time synchronisation
  • CT/VT and contact wiring

What is shown on screen?

  • Busbar voltages (kV)
  • Feeder active and reactive power
  • Phase currents
  • Breaker and disconnector positions
  • Local / remote control mode
  • Transformer tap position
  • Transformer oil and winding temperature
  • Relay trip and fault signals
  • DC battery and charger status
LevelRole
1. SCADA workstationLive single-line view, remote switching, alarm and event logs, measurement archive
2. Redundant gatewayCollects field data, translates protocols and applies GPS time stamps; if one of the A/B units fails, the other takes over
3. Field devices (relays and meters)Protection relays, feeder control units, older-generation relays and power analysers

Beyond monitoring: fault and protection analysis

  • Live tracking of relays and control units over IEC 61850
  • Reviewing COMTRADE fault records to find where and how a fault developed
  • Assessing protection coordination between relays
  • Preparing relay setting proposals based on measured network data
  • Forwarding collected data to upstream centres over IEC 60870-5-104/101

In TEİAŞ substations we support SCADA applications running on IEC 61850, IEC 60870-5-101/104, DNP3 and Modbus Serial/TCP, from site survey through to commissioning.

Central energy management, web and mobile access

Several plants or buildings can be monitored from one centre. Data is organised in a hierarchy, so you can drill down from the plant total to a single meter.

Plant
→
Department
→
Line
→
Machine
→
Meter

Access from anywhere

Screens can be reached from a computer, tablet or phone through a web browser. Remote access depends on user permissions; each user sees only the areas they are responsible for.

Benefits of an energy monitoring system

  • Lower energy costs
  • Hidden losses brought to light
  • Higher production efficiency
  • Unplanned and unnecessary consumption prevented
  • Decisions based on measurement, not estimates
  • Energy performance monitored continuously

How quickly does the investment pay back?

Spending on an energy monitoring system is recovered through the savings it brings; this period is called the payback period. The system first makes consumption visible, and as the abnormal consumption it finds is fixed, energy bills fall.

ItemExample amount
System investment1,000,000 TL
Yearly energy saving700,000 TL
Maintenance and operating gains300,000 TL
Total yearly gain≈ 1,000,000 TL
Payback period≈ 1 year

The figures are for illustration; the real period depends on plant size, energy intensity and the losses found. In practice the biggest gain comes from making previously unmeasured losses visible. Fixing compressed air leaks alone can cover a significant part of the investment.

The YOM LAB energy monitoring solution

Measure
→
Collect
→
Monitor
→
Analyse
→
Alert
→
Report
→
Optimise

YOM LAB energy monitoring solutions track electricity and other energy sources in real time, analyse them and evaluate them with AI support. This helps businesses reduce energy costs and losses while basing production decisions on measurement.

How we start a project

  1. Site survey: We walk the plant and define the energy flow and measuring points.
  2. Hardware selection: Analysers, meters, heat meters and the wireless network are planned.
  3. Software: Screens, alarms, KPIs and reports are prepared for your business.
  4. Commissioning and support: The system is started up, users are trained and ongoing support is provided.

Let's see where your energy goes

Tell us about your plant and goals; we will define the right measuring points and installation method together.