✔ Our Services

Environmental Monitoring Solutions Monitor conditions in buildings, fields, greenhouses, machines and facilities remotely with wireless sensors

When values such as temperature, humidity, air quality or vibration stay within the right range, product quality is protected, livestock stay healthy and equipment lasts longer. The problem is that small deviations are often noticed only once the damage is done.

At YOM LAB we build environmental monitoring systems for buildings, fields, greenhouses, machines and facilities. With Wi-Fi and LoRa wireless communication sensors are placed without running cables, and readings can be followed on web and mobile screens from anywhere with internet access.

Values we monitor

  • Temperature
  • Humidity
  • CO₂
  • Ammonia and other gases
  • PM1 / PM2.5
  • VOC
  • Door status
  • Differential pressure
  • Air velocity
  • Soil moisture
  • Light
  • Vibration
  • Water level and leaks

On this page

What is environmental monitoring?

Environmental monitoring automation is a secure software and hardware solution that monitors, analyses and helps you manage the physical spaces and equipment in your facility, together with the digital systems that run them, in real time. Manual checks show only certain moments of the day; automatic monitoring records every moment, including nights, weekends and holidays.

The system works in four basic steps:

Data collectionall sensors in one placeEvaluationlimit and status checkNotificationright person, right timeReportingpermanent records and analysis
  • Data collection: Data from different sources such as temperature, humidity, water leaks, door status, energy and air quality is brought together on a single platform. Monitoring modules in the field feed this flow without interruption.
  • Evaluation: Each incoming value is compared with the limits defined for that point and classified as normal, warning or alarm.
  • Notification: When a value goes out of range, the responsible person is informed by e-mail, SMS, voice call or mobile notification.
  • Reporting: Historical data is presented in charts and tables, and permanent records are kept for inspections and analysis.

Our solutions

Each area has its own values to watch and its own installation conditions, so we shape our solutions around the application.

Building monitoring

Comfort conditions and technical rooms are tracked in offices, schools, hospitals and commercial buildings.

  • Temperature, humidity and CO₂ per room
  • Server and electrical room monitoring
  • Water leak and door status alarms

Field monitoring

On large plots without power infrastructure, soil and weather conditions are tracked with long-range wireless sensors.

  • Soil moisture and temperature
  • Air temperature, humidity and frost risk
  • Support for irrigation timing

Greenhouse monitoring

Plant growth needs different climate conditions by day and by night.

  • Temperature, humidity, CO₂ and light
  • Heating, ventilation and humidification control
  • Comparison between sections

Machine monitoring

Operating conditions are tracked so faults are noticed before they grow and unplanned stoppages fall.

  • Vibration and surface temperature
  • Run and stop times
  • Current and energy consumption

Facility monitoring

Production, storage and auxiliary areas are brought together on a single screen.

  • Warehouse, production area and cold room conditions
  • Gas leaks and air quality
  • Tank levels and differential pressure

How does an environmental monitoring system work?

Readings from the sensors are sent over a wireless network to the server, where they are stored and compared with the limits. Results reach users as web screens, mobile views, alarm notifications and reports.

Field Communication Central Users Buildingtemp, humidity, CO₂ Machinevibration, temp GreenhouseCO₂, humidity, light Fieldsoil moisture Wi-Fi networkaccess point LoRa gatewaylong range Server / SCADAlogging, alarms Databasehistory Web and mobileaccess anywhere Alarmse-mail, SMS ReportsExcel, PDF Remote controlfan, heater, pump Wi-Fi link LoRa link
  • Field: Sensors suited to the application measure the environment.
  • Communication: Data is collected over Wi-Fi inside buildings and over LoRa across large open areas. Wired connections through a PLC or RTU are also used when needed.
  • Central: The server or SCADA software stores the data, checks limits and raises alarms.
  • Users: Values are followed on web and mobile screens; alarms are sent by e-mail or SMS.

Wi-Fi and LoRa wireless communication

Wireless communication is what makes environmental monitoring fast and economical. Cable routes, trunking work and long installation times disappear, and sensors can be placed exactly where the measurement is most accurate. Depending on the size and infrastructure of the area, we use one of the two technologies or both together.

Wi-FiLoRa / LoRaWAN
RangeIndoors, areas close to an access pointOn the order of kilometres in open areas; passes through walls better indoors
PowerUsually needs a constant power supplyVery low consumption; can run on batteries for a long time
Data volumeHigh; suits frequent readings and large dataLow; ideal for periodic measurement values
InfrastructureThe existing Wi-Fi network can be usedOne or a few LoRa gateways cover a wide area
Best suited forBuildings, offices, production areas, machinesFields, greenhouses, spread-out sites, points without power

Signal measurements are taken during the site survey. Extra access points or gateways are planned in advance for areas that weaken the signal, such as metal-panelled warehouses and thick concrete structures.

Sensors we use

SensorWhat does it measure?Where does it matter?
Temperature and humidityAmbient temperature and relative humidityAll areas; especially cold stores, greenhouses and mushroom farms
Carbon dioxide (CO₂)CO₂ concentration in the airGreenhouses, mushroom farms, poultry houses, crowded indoor spaces
GasGases such as ammonia, carbon monoxide and refrigerantPoultry houses, boiler rooms, cooling systems
Differential pressurePressure difference between two spaces or across a filterVentilation, filter clogging, clean rooms
Air velocityAir flow speed in a duct or spacePoultry house ventilation, HVAC ducts
Soil moisture and temperatureWater and temperature in the root zoneFields, orchards, greenhouses
LightLight intensityGreenhouses and plant growing areas
VibrationVibration level on the machine bodyMotors, pumps, fans, compressors
Particulates (PM1, PM2.5, PM10)Airborne particles of different sizesElectrical panels, technical rooms, clean areas
VOCVolatile organic compoundsPanel overheating, indoor air quality
Door statusWhether a door is open or closedCold rooms, panel and server rooms
Level and leakTank level, water on the floorWater tanks, technical rooms, server rooms

Early fire warning in electrical panels

Electrical panels and technical rooms are among the places where environmental monitoring makes the biggest difference. Fires here rarely start all at once; they develop quietly as insulation slowly degrades, a loose connection heats up or a contactor arcs. The change in the air begins long before any smoke is noticed.

That is why we interpret values together rather than looking at a single sensor. When the following start to rise at the same time, it is often a sign of trouble:

  • PM1 ↑
  • PM2.5 ↑
  • VOC ↑
  • CO ↑
  • Temperature ↑

This pattern usually points to degrading insulation, overheating cables, arcing at contactors or connection points, or the beginning of combustion inside the panel.

Why measure particles?

When a cable sheath or insulation material starts to scorch, the first particles released are very small. PM1 rises first, followed by PM2.5; PM10 becomes noticeable only once the fire grows. That is why PM1 and PM2.5 readings are what really matter for early warning.

Early warning window Fire develops Alarm limit PM1 PM2.5 PM10 First alarm Time Particle density

This monitoring does not replace the fire detection system required by regulations; it complements it as an additional safety layer that lets you see the problem at an earlier stage.

Sector applications

In some sectors environmental conditions are the production itself. In these areas we build the monitoring system around the needs of the sector.

Industrial poultry houses

Animal health and yield depend on keeping temperature, humidity and ventilation in balance.

  • Temperature and humidity tracking
  • Ammonia and CO₂ levels
  • Ventilation and air velocity control

Mushroom farms

Mushroom growth is very sensitive to humidity and CO₂; each growing stage has its own ideal values.

  • High humidity tracking
  • CO₂ monitoring by stage
  • Temperature control per room

Cold storage

Shelf life and food safety depend on temperature being kept continuously and on record.

  • Continuous temperature logging
  • Humidity tracking
  • Gas leak and door-left-open alarms

Server and electrical rooms

In rooms holding critical equipment, overheating and flooding lead to serious losses.

  • Temperature and humidity tracking
  • Water leak detection
  • Air conditioning failure alarm

PLCs, RTUs, controllers and custom devices

Depending on the site, we work with the PLCs, RTUs and controllers widely used in industry. When the system needs to connect to your existing automation, control equipment or collect many wired sensors, these devices provide a reliable foundation.

Where off-the-shelf products fall short, we develop custom devices. Because we can design everything from the electronics to the firmware, we have the flexibility to choose the hardware that best fits the project in terms of measurement, communication and cost.

  • Application-specific sensor and measurement boards
  • Battery-powered Wi-Fi and LoRa wireless nodes
  • Gateways that connect different protocols
  • Enclosures suited to dust, humidity, ammonia and low temperatures
  • Designs that lower unit cost in projects with many measuring points

Alarms and remote control

When a value leaves its range, the system warns you without delay. Alarms are grouped by priority and area, so each person receives only the notifications for the areas they are responsible for.

  • Upper and lower limit violations
  • Deviations that last longer than a set time
  • Sensor, network or power failures
  • E-mail, SMS, voice call and mobile notifications

Besides following values from a phone or tablet, equipment such as fans, heaters, humidifiers and pumps can be started and stopped remotely, or switched automatically by defined rules.

Records and reporting

Every measurement is stored with its time stamp. These records give a reliable basis both for business decisions and for inspections.

  • Hourly, daily, weekly and monthly reports
  • Comparative charts by area and room
  • Alarm history and response records
  • Excel and PDF output, sent automatically by e-mail

In food, pharmaceutical and cold chain applications, the temperature records requested during inspections can be prepared from these reports.

Installation and project process

Surveyarea and needsDesignsensor placementInstallationsensors and networkCommissioningalarms and screensSupportmaintenance and calibration

What we pay attention to

  • The right sensor for the environment: Sensors and enclosures are chosen to withstand low temperatures in cold stores, dust and ammonia in poultry houses, and rain and sun in the field.
  • Correct placement: Sensors are placed at points that truly represent the space, not misleading spots such as doorways, heater or fan outlets.
  • Outages: Measures are taken so alarms are still raised and no data is lost when the network or power fails.
  • Calibration: Periodic checks and calibration tracking keep the measurements reliable.

Benefits of environmental monitoring

  • Lower risk of product loss, waste and disease
  • Problems noticed before damage occurs
  • Staff can see conditions without going on site
  • Fewer unplanned machine stoppages
  • No unnecessary energy use in heating, cooling and ventilation
  • Ready, reliable records for inspections

Integration with SCADA and existing systems

The environmental monitoring system can run on its own or become part of your existing automation infrastructure. Data can be added to ATLAS SCADA screens and passed on to other software.

  • Wi-Fi
  • LoRa / LoRaWAN
  • MQTT
  • Modbus RTU
  • Modbus TCP
  • OPC UA
  • PLC
  • RTU

Energy consumption can also be monitored over the same infrastructure. See our Energy Monitoring Solutions page for details.

Which area would you like to monitor?