Environmental Monitoring Solutions
Monitor conditions in buildings, fields, greenhouses, machines and facilities remotely with wireless sensors
When values such as temperature, humidity, air quality or vibration stay within the right range, product quality is protected, livestock stay healthy and equipment lasts longer. The problem is that small deviations are often noticed only once the damage is done.
At YOM LAB we build environmental monitoring systems for buildings, fields, greenhouses, machines and facilities. With Wi-Fi and LoRa wireless communication sensors are placed without running cables, and readings can be followed on web and mobile screens from anywhere with internet access.
Environmental monitoring automation is a secure software and hardware solution that monitors, analyses and helps you manage the physical spaces and equipment in your facility, together with the digital systems that run them, in real time. Manual checks show only certain moments of the day; automatic monitoring records every moment, including nights, weekends and holidays.
The system works in four basic steps:
Data collectionall sensors in one place→Evaluationlimit and status check→Notificationright person, right time→Reportingpermanent records and analysis
Data collection: Data from different sources such as temperature, humidity, water leaks, door status, energy and air quality is brought together on a single platform. Monitoring modules in the field feed this flow without interruption.
Evaluation: Each incoming value is compared with the limits defined for that point and classified as normal, warning or alarm.
Notification: When a value goes out of range, the responsible person is informed by e-mail, SMS, voice call or mobile notification.
Reporting: Historical data is presented in charts and tables, and permanent records are kept for inspections and analysis.
Our solutions
Each area has its own values to watch and its own installation conditions, so we shape our solutions around the application.
Building monitoring
Comfort conditions and technical rooms are tracked in offices, schools, hospitals and commercial buildings.
Temperature, humidity and CO₂ per room
Server and electrical room monitoring
Water leak and door status alarms
Field monitoring
On large plots without power infrastructure, soil and weather conditions are tracked with long-range wireless sensors.
Soil moisture and temperature
Air temperature, humidity and frost risk
Support for irrigation timing
Greenhouse monitoring
Plant growth needs different climate conditions by day and by night.
Temperature, humidity, CO₂ and light
Heating, ventilation and humidification control
Comparison between sections
Machine monitoring
Operating conditions are tracked so faults are noticed before they grow and unplanned stoppages fall.
Vibration and surface temperature
Run and stop times
Current and energy consumption
Facility monitoring
Production, storage and auxiliary areas are brought together on a single screen.
Warehouse, production area and cold room conditions
Gas leaks and air quality
Tank levels and differential pressure
How does an environmental monitoring system work?
Readings from the sensors are sent over a wireless network to the server, where they are stored and compared with the limits. Results reach users as web screens, mobile views, alarm notifications and reports.
Field: Sensors suited to the application measure the environment.
Communication: Data is collected over Wi-Fi inside buildings and over LoRa across large open areas. Wired connections through a PLC or RTU are also used when needed.
Central: The server or SCADA software stores the data, checks limits and raises alarms.
Users: Values are followed on web and mobile screens; alarms are sent by e-mail or SMS.
Wireless communication is what makes environmental monitoring fast and economical. Cable routes, trunking work and long installation times disappear, and sensors can be placed exactly where the measurement is most accurate. Depending on the size and infrastructure of the area, we use one of the two technologies or both together.
Wi-Fi
LoRa / LoRaWAN
Range
Indoors, areas close to an access point
On the order of kilometres in open areas; passes through walls better indoors
Power
Usually needs a constant power supply
Very low consumption; can run on batteries for a long time
Data volume
High; suits frequent readings and large data
Low; ideal for periodic measurement values
Infrastructure
The existing Wi-Fi network can be used
One or a few LoRa gateways cover a wide area
Best suited for
Buildings, offices, production areas, machines
Fields, greenhouses, spread-out sites, points without power
Signal measurements are taken during the site survey. Extra access points or gateways are planned in advance for areas that weaken the signal, such as metal-panelled warehouses and thick concrete structures.
Sensors we use
Sensor
What does it measure?
Where does it matter?
Temperature and humidity
Ambient temperature and relative humidity
All areas; especially cold stores, greenhouses and mushroom farms
Gases such as ammonia, carbon monoxide and refrigerant
Poultry houses, boiler rooms, cooling systems
Differential pressure
Pressure difference between two spaces or across a filter
Ventilation, filter clogging, clean rooms
Air velocity
Air flow speed in a duct or space
Poultry house ventilation, HVAC ducts
Soil moisture and temperature
Water and temperature in the root zone
Fields, orchards, greenhouses
Light
Light intensity
Greenhouses and plant growing areas
Vibration
Vibration level on the machine body
Motors, pumps, fans, compressors
Particulates (PM1, PM2.5, PM10)
Airborne particles of different sizes
Electrical panels, technical rooms, clean areas
VOC
Volatile organic compounds
Panel overheating, indoor air quality
Door status
Whether a door is open or closed
Cold rooms, panel and server rooms
Level and leak
Tank level, water on the floor
Water tanks, technical rooms, server rooms
Early fire warning in electrical panels
Electrical panels and technical rooms are among the places where environmental monitoring makes the biggest difference. Fires here rarely start all at once; they develop quietly as insulation slowly degrades, a loose connection heats up or a contactor arcs. The change in the air begins long before any smoke is noticed.
That is why we interpret values together rather than looking at a single sensor. When the following start to rise at the same time, it is often a sign of trouble:
PM1 ↑
PM2.5 ↑
VOC ↑
CO ↑
Temperature ↑
This pattern usually points to degrading insulation, overheating cables, arcing at contactors or connection points, or the beginning of combustion inside the panel.
Why measure particles?
When a cable sheath or insulation material starts to scorch, the first particles released are very small. PM1 rises first, followed by PM2.5; PM10 becomes noticeable only once the fire grows. That is why PM1 and PM2.5 readings are what really matter for early warning.
This monitoring does not replace the fire detection system required by regulations; it complements it as an additional safety layer that lets you see the problem at an earlier stage.
In some sectors environmental conditions are the production itself. In these areas we build the monitoring system around the needs of the sector.
Industrial poultry houses
Animal health and yield depend on keeping temperature, humidity and ventilation in balance.
Temperature and humidity tracking
Ammonia and CO₂ levels
Ventilation and air velocity control
Mushroom farms
Mushroom growth is very sensitive to humidity and CO₂; each growing stage has its own ideal values.
High humidity tracking
CO₂ monitoring by stage
Temperature control per room
Cold storage
Shelf life and food safety depend on temperature being kept continuously and on record.
Continuous temperature logging
Humidity tracking
Gas leak and door-left-open alarms
Server and electrical rooms
In rooms holding critical equipment, overheating and flooding lead to serious losses.
Temperature and humidity tracking
Water leak detection
Air conditioning failure alarm
PLCs, RTUs, controllers and custom devices
Depending on the site, we work with the PLCs, RTUs and controllers widely used in industry. When the system needs to connect to your existing automation, control equipment or collect many wired sensors, these devices provide a reliable foundation.
Where off-the-shelf products fall short, we develop custom devices. Because we can design everything from the electronics to the firmware, we have the flexibility to choose the hardware that best fits the project in terms of measurement, communication and cost.
Application-specific sensor and measurement boards
Battery-powered Wi-Fi and LoRa wireless nodes
Gateways that connect different protocols
Enclosures suited to dust, humidity, ammonia and low temperatures
Designs that lower unit cost in projects with many measuring points
Alarms and remote control
When a value leaves its range, the system warns you without delay. Alarms are grouped by priority and area, so each person receives only the notifications for the areas they are responsible for.
Upper and lower limit violations
Deviations that last longer than a set time
Sensor, network or power failures
E-mail, SMS, voice call and mobile notifications
Besides following values from a phone or tablet, equipment such as fans, heaters, humidifiers and pumps can be started and stopped remotely, or switched automatically by defined rules.
Every measurement is stored with its time stamp. These records give a reliable basis both for business decisions and for inspections.
Hourly, daily, weekly and monthly reports
Comparative charts by area and room
Alarm history and response records
Excel and PDF output, sent automatically by e-mail
In food, pharmaceutical and cold chain applications, the temperature records requested during inspections can be prepared from these reports.
Installation and project process
Surveyarea and needs→Designsensor placement→Installationsensors and network→Commissioningalarms and screens→Supportmaintenance and calibration
What we pay attention to
The right sensor for the environment: Sensors and enclosures are chosen to withstand low temperatures in cold stores, dust and ammonia in poultry houses, and rain and sun in the field.
Correct placement: Sensors are placed at points that truly represent the space, not misleading spots such as doorways, heater or fan outlets.
Outages: Measures are taken so alarms are still raised and no data is lost when the network or power fails.
Calibration: Periodic checks and calibration tracking keep the measurements reliable.
Benefits of environmental monitoring
Lower risk of product loss, waste and disease
Problems noticed before damage occurs
Staff can see conditions without going on site
Fewer unplanned machine stoppages
No unnecessary energy use in heating, cooling and ventilation
The environmental monitoring system can run on its own or become part of your existing automation infrastructure. Data can be added to ATLAS SCADA screens and passed on to other software.
Wi-Fi
LoRa / LoRaWAN
MQTT
Modbus RTU
Modbus TCP
OPC UA
PLC
RTU
Energy consumption can also be monitored over the same infrastructure. See our Energy Monitoring Solutions page for details.
Which area would you like to monitor?
Tell us about the area and the values you want to watch; we will choose the right sensors, communication method and installation plan together.